Hamilton C1 Compact Ventilator Raleigh Durham Medical


Home

Hamilton Ventilator Circuits

Accesories

Hamilton C1 Acceseries


 260087

260182



HAMILTON-C1
Minimum Size for Maximum Performance

Requiring only a minimum of space, the HAMILTON-C1 mechanical ventilator combines invasive and noninvasive modes as well as highflow oxygen therapy with maximum mobility. The integrated high-performance turbine enables the HAMILTON-C1 to be completely independentfrom compressed air. This makes it an ideal companion for all patient groups in the intensivecare units, emergency wards, recovery rooms or intermediate care as well as in long-term acutecare facilities and during intrahospital transport.


Hamilton C1 Compact Ventilator Raleigh Durham Medical    

Adult, pediatric, and neonatal ventilation.
More than 4 hours of battery operating time.
Independence from gas cylinders orcompressors.
Noninvasive ventilation and integrated highflow oxygen therapy.
Advanced ventilation modes, including ASV®- Adaptive Support Ventilation.

Hamilton C1 Compact Ventilator Raleigh Durham Medical


The Hamilton C1 is Compact and Convenient for Intrahospital Transport


The high-performance turbine enables the HAMILTON-C1 mechanical ventilator to be completely independent from compressed air, and its Integrated High-Capacity Battery allows you to ventilate yourpatients During Intrahospital Transport without the need for an external power source. The compact design of the HAMILTON-C1 mechanical ventilator makes handling much easier.

Hamilton C1 Compact Ventilator Raleigh Durham Medical      Hamilton C1 Compact Ventilator Raleigh Durham Medical     

Hamilton C1 Compact Ventilator Ease of Use


In close cooperation with users and ventilation experts, our engineers have designed a user interface that is particularly intuitive. Switching between the HAMILTON-C1 and all other Hamilton Medical ventilators is easy because they are alloperated according to the same principles.
The Ventilation Cockpit on the HAMILTON-C1 consolidates the monitoring data and displays it as intuitive graphics. These provide a quick overview of the patient’s current ventilation status and provide a reliable basis for therapy decisions.
" Small but mighty! Despite its Compact Size, the HAMILTON-C1 is a fully featured ventilator for use in almost any environment. "





The Ventilation Cockpit.

1 Main monitoring parameters.
All of the main monitoring parameters at a
glance. The large characters allow you to see
them even from a distance.

2 Dynamic Lung.
One quick look shows you tidal volume, lung
compliance, patient triggering, and resistance in
real-time. The lungs expand and contract in
synchrony with the actual breaths.

3 Vent Status.
The Vent Status panel displays six parameters
related to the patient’s dependence on the
ventilator. When all values are in the weaning
zone, the panel is framed in green, indicating that
spontaneous breathing trials or extubation can be
considered.

4 Direct access to main controls.
Access and adjust the most important controls for.


Hamilton C1 Compact Ventilator Raleigh Durham Medical


The HAMILTON-C1 Compact Ventilator
combines invasive and noninvasive modes as well as high flow oxygen therapy with maximum mobility.


Adaptive, lung-protective ventilation with ASV
Supports the earliest possible spontaneous breathing by the patient
Shortens the ventilation time in various patient groups
High-performance noninvasive ventilation (NIV)
Integrated high-performance turbine supplies a peak flow rate of up to 260 l/min
Optimal performance is ensured even with large leaks
Integrated high flow oxygen therapy
Reduces the need for intubation
Lowers the risk of reintubation within 72 hours
Speaking valve
Can be used in pressure-controlled modes (PCV+, PSIMV+, SPONT)


Adaptive Support Ventilation (ASV) adjusts respiratory rate, tidal volume, and inspiratory time continuously, depending on the patient’s lung mechanics and effort. ASV adapts ventilation breath-by-breath, 24 hours a day, and from intubation to extubation.
High-performance noninvasive ventilation (NIV) is enabled by the ventilator’s integrated high-performance turbine and peakflow rate of up to 260 l/min. Optimal flow delivery is ensured even in the event of large leaks.
Integrated high flow oxygen therapy can be applied using the same device and breathing circuit, simply by changing the patient interface. Active humidification is recommended for greater patient comfort. With the optional integrated high flow oxygentherapy, the ventilator offers you a range of ventilation and therapy options inone device.
Speaking valve is an optional feature enabling the use of conventional speaking valves in pressure-controlled modes (PCV+, PSIMV+, SPONT). Monitoring, triggering, and alarm management have been adjusted to allow their use


Hamilton C1 Compact Ventilator Raleigh Durham Medical      Hamilton C1 Compact Ventilator Raleigh Durham Medical     

Weight
4.9 kg (10.8 lb) 16.9 kg (37.3 lb) with trolley The trolley can accommodate a maximum safe working load of 44 kg (97 lb).
Dimensions
See graphic above
Monitor Type: color Size: 640 x 480 pixels, 8.4 in (214 mm) diagonal
Trolley accessories
HAMILTON-H900 mounting system, optional O2 bottle holding system, optional tubing support arm.